題名: Find the Discrepancy of the MRI Images by the Second Moment and Geometry Comparison Technique
作者: Su, Ching-Liang
關鍵字: MRI image inspection
MRI image movement
image subtraction
geometry comparison
期刊名/會議名稱: 2000 ICS會議
摘要: This research investigates the techniques using the image subtraction to find the discrepancy between the healthy and illness MRI images. The technique developed in this research moves the healthy MRI image to overlap with the illness MRI image. Then, the healthy MRI image and the illness MRI image are aligned to the same orientation. After the healthy MRI image overlapped with the illness MRI image, the illness MRI image is subtracted from the healthy MRI image. If there is discrepancy in the illness MRI image, after the image subtraction, the discrepancy will remain in the subtracted result. From beginning to end the inspection is done by the machine automatically. There is no further human effort involved. The technique developed in this research can very accurately find the discrepancy of the healthy and illness images. By the orientations of the MRI images, the healthy MRI image and the illness MRI image can be aligned to the same orientation. The detailed process of image rotation is addressed in this paper.
日期: 2006-11-17T06:26:13Z
分類:2000年 ICS 國際計算機會議

文件中的檔案:
檔案 描述 大小格式 
ce07ics002000000152.pdf1.51 MBAdobe PDF檢視/開啟


在 DSpace 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。